an existing DBus connection.
This is needed by the python bindings, was done the same way
in edbus1, so it should fit here also
NOTE: I did not test this yet, and I'm not into the edbus code,
so I please who know the code to give a look. thanks
NOTE2: I don't think this need Changelog and stuff as we are probably
the only users of this function, let me know if i'm wrong
type is an enum which can be 0. Make sure that it isn't before accessing
shared_connections[type - 1]
Found with klocwork
Signed-off-by: Daniel Willmann <d.willmann@samsung.com>
If we pass the last argument as TRUE, that means user want to know the actual
bus id of the bus name and if the bus name is not registered it never notify
the user.
This bug was insert when fixing another one, because of that there more code
here to fix the previous bug too.
Patch by: José Roberto de Souza <zezsouza@gmail.com>
SVN revision: 83082
When an extra argument didn't match, instead of going to the next signal
handler we were skiping to next extra match argument because we were
calling "continue" inside EINA_INLIST_FOREACH.
Patch by: José Roberto de Souza <zehortigoza@profusion.mobi>
SVN revision: 82351
Hack to fix the connection name leak. The problem is that each signal
handler has a reference to the FDO_BUS connection name and when the
penultimate connection name is released (and therefore its signal
handler), FDO_BUS is released, too.
Check if cn is still in the hash before trying to free it.
Patch by: Ulisses Furquim <ulisses@profusion.mobi>
SVN revision: 82077
Make sure the next signal handler for the connection is always known and
not vanish under us.
Patch by: Ulisses Furquim <ulisses@profusion.mobi>
SVN revision: 81847