Summary:
do not return yet in case of edge items if looping
is disabled. try to select/focus last item.
Signed-off-by: Jyotiprakash Sahoo <jp.sahoo@samsung.com>
@fix
Test Plan: elementary_test -> Gengrid 2
Reviewers: raster, singh.amitesh, cedric, SanghyeonLee
Reviewed By: SanghyeonLee
Differential Revision: https://phab.enlightenment.org/D2865
These files come from some modules in src/modules while we set out base dir to
src/lib. In result these files are search for in src/lib and not found. In the
long term we want to find out how to collect them as well but for now a working
coverage is already good.
Overall coverage rate:
lines......: 18.1% (12596 of 69412 lines)
functions..: 18.6% (1766 of 9500 functions)
Will work on getting these run by jenkins once it is back.
Summary:
When user set min max as 50, 150 with %d format, then value set as 100.
The spinner value set as '0'
Because the sd->val type is double.
Spinner entry has same problem.
@fix
Test Plan:
Set spinner format as %d.
Check the spinner value.
It's not supported.
Reviewers: Jaehyun_Cho, cedric, Hermet
Reviewed By: Hermet
Differential Revision: https://phab.enlightenment.org/D2898
Conflicts:
src/lib/elm_spinner.c
Summary:
When the scroller size changes by dragging the
corners, the calculations will miss the condition "x+w == x1 + w1".
This is because of format specific computer calculations. So,
improvisation is made in comparisons.
@ fix
Signed-off-by: Umesh Tanwar <umesh.tanwar@samsung.com>
Test Plan:
elementary_test -> scroller -> scroll to the extreme right (right arrow brightness changes).
Now, drag the lower right corner to increase the width of scroller. Drag the corner slowly to see the issue clearly.
The arrow brightness changes alternatively, instead the hbar is positioned to the extreme right.
Reviewers: Hermet, cedric, raster
Subscribers: singh.amitesh, eagleeye, SanghyeonLee, sachin.dev
Differential Revision: https://phab.enlightenment.org/D2796
Summary:
When icon is set, icon size is calculated without considering
edje base scale. This can lead to a miscalculation when
base scale is set other than 1.0.
@fix
Reviewers: seoz, woohyun, cedric, Hermet
Reviewed By: Hermet
Subscribers: cedric
Differential Revision: https://phab.enlightenment.org/D2798
Summary:
_elm_access_say() does not free the given text.
But, the text from eina_strbuf_string_steal() is not cared
from outside of _elm_access_say(), too.
It should be changed to eina_strbuf_string_get().
Test Plan: N/A
Reviewers: cedric, woohyun, kimcinoo, JackDanielZ, Hermet
Reviewed By: Hermet
Differential Revision: https://phab.enlightenment.org/D2918
Summary:
Calling the elm_config_accel_preference_get api with "none" as parameter,
it means user does not want to use acceleration.
Reviewers: Hermet
Reviewed By: Hermet
Differential Revision: https://phab.enlightenment.org/D2920