aboutsummaryrefslogtreecommitdiffstats
path: root/src/bindings/mono/eldbus_mono/eldbus_object.cs
blob: 682fda65658fc7a6a24f17384dcfff8e9a5aa254 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328

#pragma warning disable 1591

using System.Runtime.InteropServices;

using static eldbus.EldbusObjectNativeFunctions;

using IntPtr = System.IntPtr;

namespace eldbus
{

public static class EldbusObjectNativeFunctions
{
    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_get(IntPtr conn, string bus, string path);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_ref(IntPtr obj);

    [DllImport(efl.Libs.Eldbus)] public static extern void
        eldbus_object_unref(IntPtr obj);

    [DllImport(efl.Libs.Eldbus)] public static extern void
        eldbus_object_free_cb_add(IntPtr obj, IntPtr cb, IntPtr data);

    [DllImport(efl.Libs.Eldbus)] public static extern void
        eldbus_object_free_cb_del(IntPtr obj, IntPtr cb, IntPtr data);

// typedef enum
// {
//    ELDBUS_OBJECT_EVENT_IFACE_ADDED = 0, /**< a parent path must have a ObjectManager interface */
//    ELDBUS_OBJECT_EVENT_IFACE_REMOVED, /**< a parent path must have a ObjectManager interface */
//    ELDBUS_OBJECT_EVENT_PROPERTY_CHANGED, /**< a property has changes */
//    ELDBUS_OBJECT_EVENT_PROPERTY_REMOVED, /**< a property was removed */
//    ELDBUS_OBJECT_EVENT_DEL,
//    ELDBUS_OBJECT_EVENT_LAST    /**< sentinel, not a real event type */
// } Eldbus_Object_Event_Type;
//
//     [DllImport(efl.Libs.Eldbus)] public static extern void
//         eldbus_object_event_callback_add(IntPtr obj, Eldbus_Object_Event_Type type, IntPtr cb, IntPtr cb_data);
//
//     [DllImport(efl.Libs.Eldbus)] public static extern void
//         eldbus_object_event_callback_del(IntPtr obj, Eldbus_Object_Event_Type type, IntPtr cb, IntPtr cb_data);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_connection_get(IntPtr obj);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_bus_name_get(IntPtr obj);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_path_get(IntPtr obj);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_send(IntPtr obj, IntPtr msg, IntPtr cb, IntPtr cb_data, double timeout);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_signal_handler_add(IntPtr obj, string _interface, string member, IntPtr cb, IntPtr cb_data);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_method_call_new(IntPtr obj, string _interface, string member);

    // FreeDesktop.Org Methods

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_peer_ping(IntPtr obj, IntPtr cb, IntPtr data);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_peer_machine_id_get(IntPtr obj, IntPtr cb, IntPtr data);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_introspect(IntPtr obj, IntPtr cb, IntPtr data);

    [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
        eldbus_object_managed_objects_get(IntPtr obj, IntPtr cb, IntPtr data);

//     [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
//         eldbus_object_manager_interfaces_added(IntPtr obj, Eldbus_Signal_Cb cb, IntPtr cb_data);
//
//     [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
//         eldbus_object_manager_interfaces_removed(IntPtr obj, Eldbus_Signal_Cb cb, IntPtr cb_data);
}


public class Object : System.IDisposable
{

    public IntPtr Handle {get;set;} = IntPtr.Zero;
    public bool Own {get;set;} = true;

    private void InitNew(IntPtr handle, bool own)
    {
        Handle = handle;
        Own = own;
        CheckHandle();
    }

    private void CheckHandle()
    {
        if (Handle == IntPtr.Zero)
        {
            eldbus.Common.RaiseNullHandle();
        }
    }

    public Object(IntPtr handle, bool own)
    {
        InitNew(handle, own);
    }

    public Object(eldbus.Connection conn, string bus, string path)
    {
        if (conn == null)
        {
            throw new System.ArgumentNullException("conn");
        }

        if (bus == null)
        {
            throw new System.ArgumentNullException("bus");
        }

        if (path == null)
        {
            throw new System.ArgumentNullException("path");
        }

        var handle = eldbus_object_get(conn.Handle, bus, path);

        if (handle == IntPtr.Zero)
        {
            throw new SEHException("Eldbus: could not get `Object' object from eldbus_object_get");
        }

        InitNew(handle, true);
    }

    ~Object()
    {
        Dispose(false);
    }

    protected virtual void Dispose(bool disposing)
    {
        IntPtr h = Handle;
        Handle = IntPtr.Zero;
        if (h == IntPtr.Zero)
        {
            return;
        }

        if (Own)
        {
            if (disposing)
            {
                eldbus_object_unref(h);
            }
            else
            {
                Efl.Eo.Globals.ThreadSafeFreeCbExec(eldbus_object_unref, h);
            }
        }
    }

    public void Dispose()
    {
        Dispose(true);
        System.GC.SuppressFinalize(this);
    }

    public void Free()
    {
        Dispose();
    }

    public IntPtr Release()
    {
        IntPtr h = Handle;
        Handle = IntPtr.Zero;
        return h;
    }

    public eldbus.Connection GetConnection()
    {
        CheckHandle();
        var conn = eldbus_object_connection_get(Handle);

        if (conn == IntPtr.Zero)
        {
            throw new SEHException("Eldbus: could not get `Connection' object from eldbus_object_connection_get");
        }

        return new eldbus.Connection(conn, false);
    }

    public string GetBusName()
    {
        CheckHandle();
        var ptr = eldbus_object_bus_name_get(Handle);
        return Eina.StringConversion.NativeUtf8ToManagedString(ptr);
    }

    public string GetPath()
    {
        CheckHandle();
        var ptr = eldbus_object_path_get(Handle);
        return Eina.StringConversion.NativeUtf8ToManagedString(ptr);
    }

    public void Ref()
    {
        CheckHandle();
        eldbus_object_ref(Handle);
    }

    public void Unref()
    {
        CheckHandle();
        eldbus_object_unref(Handle);
    }

    public eldbus.Pending Send(eldbus.Message msg, eldbus.MessageDelegate dlgt = null, double timeout = -1)
    {
        CheckHandle();

        if (msg == null)
        {
            throw new System.ArgumentNullException("msg");
        }

        IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
        IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);

        var pending_hdl = eldbus_object_send(Handle, msg.Handle, cb_wrapper, cb_data, timeout);

        if (pending_hdl == IntPtr.Zero)
        {
            throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_send");
        }

        return new eldbus.Pending(pending_hdl, false);
    }

    public eldbus.Message NewMethodCall(string _interface, string member)
    {
        CheckHandle();

        var hdl = eldbus_object_method_call_new(Handle, _interface, member);

        if (hdl == IntPtr.Zero)
        {
            throw new SEHException("Eldbus: could not get `Message' object from eldbus_object_method_call_new");
        }

        return new eldbus.Message(hdl, false);
    }

    public eldbus.Pending PeerPing(eldbus.MessageDelegate dlgt = null)
    {
        CheckHandle();

        IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
        IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);

        var pending_hdl = eldbus_object_peer_ping(Handle, cb_wrapper, cb_data);

        if (pending_hdl == IntPtr.Zero)
        {
            throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_peer_ping");
        }

        return new eldbus.Pending(pending_hdl, false);
    }

    public eldbus.Pending GetPeerMachineId(eldbus.MessageDelegate dlgt = null)
    {
        CheckHandle();

        IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
        IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);

        var pending_hdl = eldbus_object_peer_machine_id_get(Handle, cb_wrapper, cb_data);

        if (pending_hdl == IntPtr.Zero)
        {
            throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_peer_machine_id_get");
        }

        return new eldbus.Pending(pending_hdl, false);
    }

    public eldbus.Pending Introspect(eldbus.MessageDelegate dlgt = null)
    {
        CheckHandle();

        IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
        IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);

        var pending_hdl = eldbus_object_introspect(Handle, cb_wrapper, cb_data);

        if (pending_hdl == IntPtr.Zero)
        {
            throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_introspect");
        }

        return new eldbus.Pending(pending_hdl, false);
    }

    public eldbus.Pending GetManagedObjects(eldbus.MessageDelegate dlgt = null)
    {
        CheckHandle();

        IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
        IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);

        var pending_hdl = eldbus_object_managed_objects_get(Handle, cb_wrapper, cb_data);

        if (pending_hdl == IntPtr.Zero)
        {
            throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_managed_objects_get");
        }

        return new eldbus.Pending(pending_hdl, false);
    }
}

}