318 lines
9.7 KiB
C#
318 lines
9.7 KiB
C#
|
|
#pragma warning disable 1591
|
|
|
|
using System.Runtime.InteropServices;
|
|
|
|
using static eldbus.EldbusObjectNativeFunctions;
|
|
|
|
using IntPtr = System.IntPtr;
|
|
|
|
namespace eldbus {
|
|
|
|
|
|
public static class EldbusObjectNativeFunctions
|
|
{
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_get(IntPtr conn, string bus, string path);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_ref(IntPtr obj);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern void
|
|
eldbus_object_unref(IntPtr obj);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern void
|
|
eldbus_object_free_cb_add(IntPtr obj, IntPtr cb, IntPtr data);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern void
|
|
eldbus_object_free_cb_del(IntPtr obj, IntPtr cb, IntPtr data);
|
|
|
|
// typedef enum
|
|
// {
|
|
// ELDBUS_OBJECT_EVENT_IFACE_ADDED = 0, /**< a parent path must have a ObjectManager interface */
|
|
// ELDBUS_OBJECT_EVENT_IFACE_REMOVED, /**< a parent path must have a ObjectManager interface */
|
|
// ELDBUS_OBJECT_EVENT_PROPERTY_CHANGED, /**< a property has changes */
|
|
// ELDBUS_OBJECT_EVENT_PROPERTY_REMOVED, /**< a property was removed */
|
|
// ELDBUS_OBJECT_EVENT_DEL,
|
|
// ELDBUS_OBJECT_EVENT_LAST /**< sentinel, not a real event type */
|
|
// } Eldbus_Object_Event_Type;
|
|
//
|
|
// [DllImport(efl.Libs.Eldbus)] public static extern void
|
|
// eldbus_object_event_callback_add(IntPtr obj, Eldbus_Object_Event_Type type, IntPtr cb, IntPtr cb_data);
|
|
//
|
|
// [DllImport(efl.Libs.Eldbus)] public static extern void
|
|
// eldbus_object_event_callback_del(IntPtr obj, Eldbus_Object_Event_Type type, IntPtr cb, IntPtr cb_data);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_connection_get(IntPtr obj);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_bus_name_get(IntPtr obj);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_path_get(IntPtr obj);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_send(IntPtr obj, IntPtr msg, IntPtr cb, IntPtr cb_data, double timeout);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_signal_handler_add(IntPtr obj, string _interface, string member, IntPtr cb, IntPtr cb_data);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_method_call_new(IntPtr obj, string _interface, string member);
|
|
|
|
// FreeDesktop.Org Methods
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_peer_ping(IntPtr obj, IntPtr cb, IntPtr data);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_peer_machine_id_get(IntPtr obj, IntPtr cb, IntPtr data);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_introspect(IntPtr obj, IntPtr cb, IntPtr data);
|
|
|
|
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
eldbus_object_managed_objects_get(IntPtr obj, IntPtr cb, IntPtr data);
|
|
|
|
// [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
// eldbus_object_manager_interfaces_added(IntPtr obj, Eldbus_Signal_Cb cb, IntPtr cb_data);
|
|
//
|
|
// [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
|
|
// eldbus_object_manager_interfaces_removed(IntPtr obj, Eldbus_Signal_Cb cb, IntPtr cb_data);
|
|
}
|
|
|
|
|
|
public class Object : System.IDisposable
|
|
{
|
|
|
|
public IntPtr Handle {get;set;} = IntPtr.Zero;
|
|
public bool Own {get;set;} = true;
|
|
|
|
private void InitNew(IntPtr handle, bool own)
|
|
{
|
|
Handle = handle;
|
|
Own = own;
|
|
CheckHandle();
|
|
}
|
|
|
|
private void CheckHandle()
|
|
{
|
|
if (Handle == IntPtr.Zero)
|
|
{
|
|
eldbus.Common.RaiseNullHandle();
|
|
}
|
|
}
|
|
|
|
public Object(IntPtr handle, bool own)
|
|
{
|
|
InitNew(handle, own);
|
|
}
|
|
|
|
public Object(eldbus.Connection conn, string bus, string path)
|
|
{
|
|
if (conn == null)
|
|
throw new System.ArgumentNullException("conn");
|
|
if (bus == null)
|
|
throw new System.ArgumentNullException("bus");
|
|
if (path == null)
|
|
throw new System.ArgumentNullException("path");
|
|
|
|
var handle = eldbus_object_get(conn.Handle, bus, path);
|
|
|
|
if (handle == IntPtr.Zero)
|
|
{
|
|
Eina.Error.RaiseIfOccurred();
|
|
throw new SEHException("Eldbus: could not get `Object' object from eldbus_object_get");
|
|
}
|
|
|
|
InitNew(handle, true);
|
|
}
|
|
|
|
~Object()
|
|
{
|
|
Dispose(false);
|
|
}
|
|
|
|
protected virtual void Dispose(bool disposing)
|
|
{
|
|
IntPtr h = Handle;
|
|
Handle = IntPtr.Zero;
|
|
if (h == IntPtr.Zero)
|
|
return;
|
|
|
|
if (Own)
|
|
eldbus_object_unref(h);
|
|
}
|
|
|
|
public void Dispose()
|
|
{
|
|
Dispose(true);
|
|
System.GC.SuppressFinalize(this);
|
|
}
|
|
|
|
public void Free()
|
|
{
|
|
Dispose();
|
|
}
|
|
|
|
public IntPtr Release()
|
|
{
|
|
IntPtr h = Handle;
|
|
Handle = IntPtr.Zero;
|
|
return h;
|
|
}
|
|
|
|
public eldbus.Connection GetConnection()
|
|
{
|
|
CheckHandle();
|
|
var conn = eldbus_object_connection_get(Handle);
|
|
|
|
if (conn == IntPtr.Zero)
|
|
{
|
|
Eina.Error.RaiseIfOccurred();
|
|
throw new SEHException("Eldbus: could not get `Connection' object from eldbus_object_connection_get");
|
|
}
|
|
|
|
return new eldbus.Connection(conn, false);
|
|
}
|
|
|
|
public string GetBusName()
|
|
{
|
|
CheckHandle();
|
|
var ptr = eldbus_object_bus_name_get(Handle);
|
|
return Marshal.PtrToStringAuto(ptr);
|
|
}
|
|
|
|
public string GetPath()
|
|
{
|
|
CheckHandle();
|
|
var ptr = eldbus_object_path_get(Handle);
|
|
return Marshal.PtrToStringAuto(ptr);
|
|
}
|
|
|
|
public void Ref()
|
|
{
|
|
CheckHandle();
|
|
eldbus_object_ref(Handle);
|
|
}
|
|
|
|
public void Unref()
|
|
{
|
|
CheckHandle();
|
|
eldbus_object_unref(Handle);
|
|
}
|
|
|
|
public eldbus.Pending Send(eldbus.Message msg, eldbus.MessageDelegate dlgt = null, double timeout = -1)
|
|
{
|
|
CheckHandle();
|
|
|
|
if (msg == null)
|
|
throw new System.ArgumentNullException("msg");
|
|
|
|
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
|
|
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
|
|
|
|
var pending_hdl = eldbus_object_send(Handle, msg.Handle, cb_wrapper, cb_data, timeout);
|
|
|
|
if (pending_hdl == IntPtr.Zero)
|
|
{
|
|
Eina.Error.RaiseIfOccurred();
|
|
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_send");
|
|
}
|
|
|
|
return new eldbus.Pending(pending_hdl, false);
|
|
}
|
|
|
|
public eldbus.Message NewMethodCall(string _interface, string member)
|
|
{
|
|
CheckHandle();
|
|
|
|
var hdl = eldbus_object_method_call_new(Handle, _interface, member);
|
|
|
|
if (hdl == IntPtr.Zero)
|
|
{
|
|
Eina.Error.RaiseIfOccurred();
|
|
throw new SEHException("Eldbus: could not get `Message' object from eldbus_object_method_call_new");
|
|
}
|
|
|
|
return new eldbus.Message(hdl, false);
|
|
}
|
|
|
|
public eldbus.Pending PeerPing(eldbus.MessageDelegate dlgt = null)
|
|
{
|
|
CheckHandle();
|
|
|
|
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
|
|
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
|
|
|
|
var pending_hdl = eldbus_object_peer_ping(Handle, cb_wrapper, cb_data);
|
|
|
|
if (pending_hdl == IntPtr.Zero)
|
|
{
|
|
Eina.Error.RaiseIfOccurred();
|
|
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_peer_ping");
|
|
}
|
|
|
|
return new eldbus.Pending(pending_hdl, false);
|
|
}
|
|
|
|
public eldbus.Pending GetPeerMachineId(eldbus.MessageDelegate dlgt = null)
|
|
{
|
|
CheckHandle();
|
|
|
|
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
|
|
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
|
|
|
|
var pending_hdl = eldbus_object_peer_machine_id_get(Handle, cb_wrapper, cb_data);
|
|
|
|
if (pending_hdl == IntPtr.Zero)
|
|
{
|
|
Eina.Error.RaiseIfOccurred();
|
|
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_peer_machine_id_get");
|
|
}
|
|
|
|
return new eldbus.Pending(pending_hdl, false);
|
|
}
|
|
|
|
public eldbus.Pending Introspect(eldbus.MessageDelegate dlgt = null)
|
|
{
|
|
CheckHandle();
|
|
|
|
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
|
|
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
|
|
|
|
var pending_hdl = eldbus_object_introspect(Handle, cb_wrapper, cb_data);
|
|
|
|
if (pending_hdl == IntPtr.Zero)
|
|
{
|
|
Eina.Error.RaiseIfOccurred();
|
|
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_introspect");
|
|
}
|
|
|
|
return new eldbus.Pending(pending_hdl, false);
|
|
}
|
|
|
|
public eldbus.Pending GetManagedObjects(eldbus.MessageDelegate dlgt = null)
|
|
{
|
|
CheckHandle();
|
|
|
|
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
|
|
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
|
|
|
|
var pending_hdl = eldbus_object_managed_objects_get(Handle, cb_wrapper, cb_data);
|
|
|
|
if (pending_hdl == IntPtr.Zero)
|
|
{
|
|
Eina.Error.RaiseIfOccurred();
|
|
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_managed_objects_get");
|
|
}
|
|
|
|
return new eldbus.Pending(pending_hdl, false);
|
|
}
|
|
|
|
}
|
|
|
|
|
|
}
|