efl/src/bindings/mono/eldbus_mono/eldbus_object.cs

318 lines
9.7 KiB
C#

#pragma warning disable 1591
using System.Runtime.InteropServices;
using static eldbus.EldbusObjectNativeFunctions;
using IntPtr = System.IntPtr;
namespace eldbus {
public static class EldbusObjectNativeFunctions
{
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_get(IntPtr conn, string bus, string path);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_ref(IntPtr obj);
[DllImport(efl.Libs.Eldbus)] public static extern void
eldbus_object_unref(IntPtr obj);
[DllImport(efl.Libs.Eldbus)] public static extern void
eldbus_object_free_cb_add(IntPtr obj, IntPtr cb, IntPtr data);
[DllImport(efl.Libs.Eldbus)] public static extern void
eldbus_object_free_cb_del(IntPtr obj, IntPtr cb, IntPtr data);
// typedef enum
// {
// ELDBUS_OBJECT_EVENT_IFACE_ADDED = 0, /**< a parent path must have a ObjectManager interface */
// ELDBUS_OBJECT_EVENT_IFACE_REMOVED, /**< a parent path must have a ObjectManager interface */
// ELDBUS_OBJECT_EVENT_PROPERTY_CHANGED, /**< a property has changes */
// ELDBUS_OBJECT_EVENT_PROPERTY_REMOVED, /**< a property was removed */
// ELDBUS_OBJECT_EVENT_DEL,
// ELDBUS_OBJECT_EVENT_LAST /**< sentinel, not a real event type */
// } Eldbus_Object_Event_Type;
//
// [DllImport(efl.Libs.Eldbus)] public static extern void
// eldbus_object_event_callback_add(IntPtr obj, Eldbus_Object_Event_Type type, IntPtr cb, IntPtr cb_data);
//
// [DllImport(efl.Libs.Eldbus)] public static extern void
// eldbus_object_event_callback_del(IntPtr obj, Eldbus_Object_Event_Type type, IntPtr cb, IntPtr cb_data);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_connection_get(IntPtr obj);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_bus_name_get(IntPtr obj);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_path_get(IntPtr obj);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_send(IntPtr obj, IntPtr msg, IntPtr cb, IntPtr cb_data, double timeout);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_signal_handler_add(IntPtr obj, string _interface, string member, IntPtr cb, IntPtr cb_data);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_method_call_new(IntPtr obj, string _interface, string member);
// FreeDesktop.Org Methods
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_peer_ping(IntPtr obj, IntPtr cb, IntPtr data);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_peer_machine_id_get(IntPtr obj, IntPtr cb, IntPtr data);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_introspect(IntPtr obj, IntPtr cb, IntPtr data);
[DllImport(efl.Libs.Eldbus)] public static extern IntPtr
eldbus_object_managed_objects_get(IntPtr obj, IntPtr cb, IntPtr data);
// [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
// eldbus_object_manager_interfaces_added(IntPtr obj, Eldbus_Signal_Cb cb, IntPtr cb_data);
//
// [DllImport(efl.Libs.Eldbus)] public static extern IntPtr
// eldbus_object_manager_interfaces_removed(IntPtr obj, Eldbus_Signal_Cb cb, IntPtr cb_data);
}
public class Object : System.IDisposable
{
public IntPtr Handle {get;set;} = IntPtr.Zero;
public bool Own {get;set;} = true;
private void InitNew(IntPtr handle, bool own)
{
Handle = handle;
Own = own;
CheckHandle();
}
private void CheckHandle()
{
if (Handle == IntPtr.Zero)
{
eldbus.Common.RaiseNullHandle();
}
}
public Object(IntPtr handle, bool own)
{
InitNew(handle, own);
}
public Object(eldbus.Connection conn, string bus, string path)
{
if (conn == null)
throw new System.ArgumentNullException("conn");
if (bus == null)
throw new System.ArgumentNullException("bus");
if (path == null)
throw new System.ArgumentNullException("path");
var handle = eldbus_object_get(conn.Handle, bus, path);
if (handle == IntPtr.Zero)
{
Eina.Error.RaiseIfOccurred();
throw new SEHException("Eldbus: could not get `Object' object from eldbus_object_get");
}
InitNew(handle, true);
}
~Object()
{
Dispose(false);
}
protected virtual void Dispose(bool disposing)
{
IntPtr h = Handle;
Handle = IntPtr.Zero;
if (h == IntPtr.Zero)
return;
if (Own)
eldbus_object_unref(h);
}
public void Dispose()
{
Dispose(true);
System.GC.SuppressFinalize(this);
}
public void Free()
{
Dispose();
}
public IntPtr Release()
{
IntPtr h = Handle;
Handle = IntPtr.Zero;
return h;
}
public eldbus.Connection GetConnection()
{
CheckHandle();
var conn = eldbus_object_connection_get(Handle);
if (conn == IntPtr.Zero)
{
Eina.Error.RaiseIfOccurred();
throw new SEHException("Eldbus: could not get `Connection' object from eldbus_object_connection_get");
}
return new eldbus.Connection(conn, false);
}
public string GetBusName()
{
CheckHandle();
var ptr = eldbus_object_bus_name_get(Handle);
return Marshal.PtrToStringAuto(ptr);
}
public string GetPath()
{
CheckHandle();
var ptr = eldbus_object_path_get(Handle);
return Marshal.PtrToStringAuto(ptr);
}
public void Ref()
{
CheckHandle();
eldbus_object_ref(Handle);
}
public void Unref()
{
CheckHandle();
eldbus_object_unref(Handle);
}
public eldbus.Pending Send(eldbus.Message msg, eldbus.MessageDelegate dlgt = null, double timeout = -1)
{
CheckHandle();
if (msg == null)
throw new System.ArgumentNullException("msg");
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
var pending_hdl = eldbus_object_send(Handle, msg.Handle, cb_wrapper, cb_data, timeout);
if (pending_hdl == IntPtr.Zero)
{
Eina.Error.RaiseIfOccurred();
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_send");
}
return new eldbus.Pending(pending_hdl, false);
}
public eldbus.Message NewMethodCall(string _interface, string member)
{
CheckHandle();
var hdl = eldbus_object_method_call_new(Handle, _interface, member);
if (hdl == IntPtr.Zero)
{
Eina.Error.RaiseIfOccurred();
throw new SEHException("Eldbus: could not get `Message' object from eldbus_object_method_call_new");
}
return new eldbus.Message(hdl, false);
}
public eldbus.Pending PeerPing(eldbus.MessageDelegate dlgt = null)
{
CheckHandle();
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
var pending_hdl = eldbus_object_peer_ping(Handle, cb_wrapper, cb_data);
if (pending_hdl == IntPtr.Zero)
{
Eina.Error.RaiseIfOccurred();
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_peer_ping");
}
return new eldbus.Pending(pending_hdl, false);
}
public eldbus.Pending GetPeerMachineId(eldbus.MessageDelegate dlgt = null)
{
CheckHandle();
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
var pending_hdl = eldbus_object_peer_machine_id_get(Handle, cb_wrapper, cb_data);
if (pending_hdl == IntPtr.Zero)
{
Eina.Error.RaiseIfOccurred();
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_peer_machine_id_get");
}
return new eldbus.Pending(pending_hdl, false);
}
public eldbus.Pending Introspect(eldbus.MessageDelegate dlgt = null)
{
CheckHandle();
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
var pending_hdl = eldbus_object_introspect(Handle, cb_wrapper, cb_data);
if (pending_hdl == IntPtr.Zero)
{
Eina.Error.RaiseIfOccurred();
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_introspect");
}
return new eldbus.Pending(pending_hdl, false);
}
public eldbus.Pending GetManagedObjects(eldbus.MessageDelegate dlgt = null)
{
CheckHandle();
IntPtr cb_wrapper = dlgt == null ? IntPtr.Zero : eldbus.Common.GetMessageCbWrapperPtr();
IntPtr cb_data = dlgt == null ? IntPtr.Zero : Marshal.GetFunctionPointerForDelegate(dlgt);
var pending_hdl = eldbus_object_managed_objects_get(Handle, cb_wrapper, cb_data);
if (pending_hdl == IntPtr.Zero)
{
Eina.Error.RaiseIfOccurred();
throw new SEHException("Eldbus: could not get `Pending' object from eldbus_object_managed_objects_get");
}
return new eldbus.Pending(pending_hdl, false);
}
}
}