If a monitor is disabled by the user, then we need to set number of

outputs to zero, and free any allocated outputs before trying to apply
settings.

Also, check for valid mode (not 0) before trying to fetch mode_info.

Signed-off-by: Chris Michael <cp.michael@samsung.com>
devs/sachiel/e19
Chris Michael 11 years ago
parent 9080e82ec4
commit bba201a892
  1. 9
      src/modules/conf_randr/e_smart_monitor.c

@ -807,7 +807,12 @@ e_smart_monitor_changes_apply(Evas_Object *obj)
/* record current values */
mode = sd->current.mode;
if (!sd->current.enabled) mode = 0;
if (!sd->current.enabled)
{
mode = 0;
noutputs = 0;
free(outputs);
}
cx = sd->current.x;
cy = sd->current.y;
@ -852,7 +857,7 @@ e_smart_monitor_changes_apply(Evas_Object *obj)
sd->crtc.orient = orient;
sd->crtc.enabled = sd->current.enabled;
if ((mode_info = ecore_x_randr_mode_info_get(root, sd->crtc.mode)))
if ((sd->crtc.mode) && (mode_info = ecore_x_randr_mode_info_get(root, sd->crtc.mode)))
{
sd->crtc.refresh_rate =
_e_smart_monitor_mode_refresh_rate_get(mode_info);