This reverts commit fba185798c.
There is not even a description why you reverted it. This is a bugfix
that fixed a bug. So talk to me what the issue is, but please stop
reverting commits silently.
so i have a situatioon where pulse is not started automagically. if
e's mixer it set to pulse... then stick to it, run pulse and keep
trying to connect every 0.2 sec until connection works. this makes
sound "just work" tm as it should...
@fix
This commit enhance the e_client_volume popup. Now you could see which sink
belongs to an e_client and allow you to control it. Sadly I haven't added a
scroller to this popup, I will add it later. Lots of calcs is needed to
display it correctly.
display really isn't uninitialized due to the logic, but compielr is
kind of right in theory... but less warnings is better so we fix the
real problems more easily. fix.
So yeah, I've literally used sed to replace every occurrence of
ecore_time_add() with ecore_timer_loop_add() because I'm reasonably
confident that no part of E has a legitimate need for timer based on the
exact current time.
It would be really nice if I'm not wrong. :)
The reason for this is the incredible spew of clock_gettime() calls I'm
seeing on an ARM system (that should have a vdso for gettime, but...)
This can amount to thousands of system calls per second.
#YOLO
If we got more than one volume sink in e_client and we change the volume
of one of them all sink of this e_client are updated to the same volume.
So don't update e_client volume if we got more than 1 sink.
T4821
emix can still have wrong values from pa, and thus the value will jump
back and later come back to the right pos:
Here a video of what is happening:
http://omicron.homeip.net/filedump/mixer_gadget_bug.ogv
Thank you morluxus!
We use the pulseaudio backend to export volume control by app.
This commit introduce 3 news shortcuts to control the volume with the current
focused window.
@features
if you click on the slider in the gadget the slider jumps a back to the
old volume and then to the new volume, this is because a pulseaudio
update is sent while the last changed event was called, but not the
drag_stop callback.
this guarantees a crash any time the default sink gets removed since it will
always re-set the about-to-be-deleted default sink as the default sink
fix T3277 probably
for the case the default sink was removed the gadget will get a new
default sink again, for the case of pa there is the possibility that
at this time the sink is still the default one, but the sink gets
removed. so we better set the default index to -1 and return just some
sink for the case the default is deleted.
If we are calling emix_config_save_state_get while in init, we are
freeing the list emix_config_save_state_restore is iterating over.
This leads to crashes.
@fix T2942
@fix T2906
We have to use void in a function declaration if we want no function
parameters. Using just empty parenthesis means the function takes an
unspecified number of parameters.
We had it correct for most declarations and this series fixes it for
the rest.
Thanks for the sparse semantic parser for pointing this out.