#include "sysinfo.h" |
|
|
|
static E_Config_DD *conf_edd = NULL; |
|
static E_Config_DD *conf_item_edd = NULL; |
|
Eina_List *sysinfo_instances = NULL; |
|
E_Module *module = NULL; |
|
Config *sysinfo_config = NULL; |
|
|
|
EINTERN void |
|
sysinfo_init(void) |
|
{ |
|
conf_item_edd = E_CONFIG_DD_NEW("Sysinfo_Config_Item", Config_Item); |
|
#undef T |
|
#undef D |
|
#define T Config_Item |
|
#define D conf_item_edd |
|
E_CONFIG_VAL(D, T, id, INT); |
|
E_CONFIG_VAL(D, T, esm, INT); |
|
E_CONFIG_VAL(D, T, batman.poll_interval, INT); |
|
E_CONFIG_VAL(D, T, batman.alert, INT); |
|
E_CONFIG_VAL(D, T, batman.alert_p, INT); |
|
E_CONFIG_VAL(D, T, batman.alert_timeout, INT); |
|
E_CONFIG_VAL(D, T, batman.suspend_below, INT); |
|
E_CONFIG_VAL(D, T, batman.force_mode, INT); |
|
#if defined HAVE_EEZE || defined __OpenBSD__ || defined __NetBSD__ |
|
E_CONFIG_VAL(D, T, batman.fuzzy, INT); |
|
#endif |
|
E_CONFIG_VAL(D, T, batman.desktop_notifications, INT); |
|
E_CONFIG_VAL(D, T, thermal.poll_interval, INT); |
|
E_CONFIG_VAL(D, T, thermal.low, INT); |
|
E_CONFIG_VAL(D, T, thermal.high, INT); |
|
E_CONFIG_VAL(D, T, thermal.sensor_type, INT); |
|
E_CONFIG_VAL(D, T, thermal.sensor_name, STR); |
|
E_CONFIG_VAL(D, T, thermal.units, INT); |
|
E_CONFIG_VAL(D, T, cpuclock.poll_interval, INT); |
|
E_CONFIG_VAL(D, T, cpuclock.restore_governor, INT); |
|
E_CONFIG_VAL(D, T, cpuclock.auto_powersave, INT); |
|
E_CONFIG_VAL(D, T, cpuclock.powersave_governor, STR); |
|
E_CONFIG_VAL(D, T, cpuclock.governor, STR); |
|
E_CONFIG_VAL(D, T, cpuclock.pstate_min, INT); |
|
E_CONFIG_VAL(D, T, cpuclock.pstate_max, INT); |
|
E_CONFIG_VAL(D, T, cpumonitor.poll_interval, INT); |
|
E_CONFIG_VAL(D, T, memusage.poll_interval, INT); |
|
E_CONFIG_VAL(D, T, netstatus.poll_interval, INT); |
|
|
|
conf_edd = E_CONFIG_DD_NEW("Sysinfo_Config", Config); |
|
#undef T |
|
#undef D |
|
#define T Config |
|
#define D conf_edd |
|
E_CONFIG_LIST(D, T, items, conf_item_edd); |
|
|
|
sysinfo_config = e_config_domain_load("module.sysinfo", conf_edd); |
|
|
|
if (!sysinfo_config) |
|
{ |
|
Config_Item *ci; |
|
|
|
sysinfo_config = E_NEW(Config, 1); |
|
ci = E_NEW(Config_Item, 1); |
|
ci->id = 0; |
|
ci->esm = E_SYSINFO_MODULE_NONE; |
|
|
|
ci->batman.poll_interval = 512; |
|
ci->batman.alert = 30; |
|
ci->batman.alert_p = 10; |
|
ci->batman.alert_timeout = 0; |
|
ci->batman.suspend_below = 0; |
|
ci->batman.force_mode = 0; |
|
ci->batman.full = -2; |
|
ci->batman.time_left = -2; |
|
ci->batman.time_full = -2; |
|
ci->batman.have_battery = -2; |
|
ci->batman.have_power = -2; |
|
#if defined HAVE_EEZE || defined __OpenBSD__ || defined __NetBSD__ |
|
ci->batman.fuzzy = 0; |
|
#endif |
|
ci->batman.desktop_notifications = 0; |
|
ci->thermal.poll_interval = 128; |
|
ci->thermal.low = 30; |
|
ci->thermal.high = 80; |
|
ci->thermal.sensor_type = SENSOR_TYPE_NONE; |
|
ci->thermal.sensor_name = NULL; |
|
ci->thermal.temp = -900; |
|
ci->thermal.units = CELSIUS; |
|
ci->cpuclock.poll_interval = 32; |
|
ci->cpuclock.restore_governor = 0; |
|
ci->cpuclock.auto_powersave = 1; |
|
ci->cpuclock.powersave_governor = NULL; |
|
ci->cpuclock.governor = NULL; |
|
ci->cpuclock.pstate_min = 1; |
|
ci->cpuclock.pstate_max = 101; |
|
ci->cpumonitor.poll_interval = 32; |
|
ci->cpumonitor.total = 0; |
|
ci->cpumonitor.idle = 0; |
|
ci->memusage.poll_interval = 32; |
|
ci->netstatus.poll_interval = 32; |
|
ci->netstatus.in = 0; |
|
ci->netstatus.out = 0; |
|
|
|
E_CONFIG_LIMIT(ci->batman.poll_interval, 4, 4096); |
|
E_CONFIG_LIMIT(ci->batman.alert, 0, 60); |
|
E_CONFIG_LIMIT(ci->batman.alert_p, 0, 100); |
|
E_CONFIG_LIMIT(ci->batman.alert_timeout, 0, 300); |
|
E_CONFIG_LIMIT(ci->batman.suspend_below, 0, 50); |
|
E_CONFIG_LIMIT(ci->batman.force_mode, 0, 2); |
|
E_CONFIG_LIMIT(ci->batman.desktop_notifications, 0, 1); |
|
E_CONFIG_LIMIT(ci->thermal.poll_interval, 1, 1024); |
|
E_CONFIG_LIMIT(ci->thermal.low, 0, 100); |
|
E_CONFIG_LIMIT(ci->thermal.high, 0, 220); |
|
E_CONFIG_LIMIT(ci->thermal.units, CELSIUS, FAHRENHEIT); |
|
E_CONFIG_LIMIT(ci->cpuclock.poll_interval, 1, 1024); |
|
E_CONFIG_LIMIT(ci->cpumonitor.poll_interval, 1, 1024); |
|
E_CONFIG_LIMIT(ci->memusage.poll_interval, 1, 1024); |
|
E_CONFIG_LIMIT(ci->netstatus.poll_interval, 1, 1024); |
|
|
|
sysinfo_config->items = eina_list_append(sysinfo_config->items, ci); |
|
} |
|
e_gadget_type_add("Batman", batman_create, NULL); |
|
e_gadget_type_add("Thermal", thermal_create, NULL); |
|
e_gadget_type_add("CpuClock", cpuclock_create, NULL); |
|
e_gadget_type_add("CpuMonitor", cpumonitor_create, NULL); |
|
e_gadget_type_add("MemUsage", memusage_create, NULL); |
|
e_gadget_type_add("NetStatus", netstatus_create, NULL); |
|
e_gadget_type_add("SysInfo", sysinfo_create, NULL); |
|
} |
|
|
|
EINTERN void |
|
sysinfo_shutdown(void) |
|
{ |
|
if (sysinfo_config) |
|
{ |
|
Config_Item *ci; |
|
EINA_LIST_FREE(sysinfo_config->items, ci) |
|
{ |
|
free(ci); |
|
} |
|
E_FREE(sysinfo_config); |
|
} |
|
E_CONFIG_DD_FREE(conf_edd); |
|
E_CONFIG_DD_FREE(conf_item_edd); |
|
|
|
e_gadget_type_del("Batman"); |
|
e_gadget_type_del("Thermal"); |
|
e_gadget_type_del("CpuClock"); |
|
e_gadget_type_del("CpuMonitor"); |
|
e_gadget_type_del("MemUsage"); |
|
e_gadget_type_del("NetStatus"); |
|
e_gadget_type_del("SysInfo"); |
|
} |
|
|
|
E_API E_Module_Api e_modapi = |
|
{ |
|
E_MODULE_API_VERSION, |
|
"Sysinfo" |
|
}; |
|
|
|
E_API void * |
|
e_modapi_init(E_Module *m) |
|
{ |
|
sysinfo_init(); |
|
|
|
module = m; |
|
sysinfo_config->module = m; |
|
return m; |
|
} |
|
|
|
E_API int |
|
e_modapi_shutdown(E_Module *m EINA_UNUSED) |
|
{ |
|
sysinfo_shutdown(); |
|
return 1; |
|
} |
|
|
|
E_API int |
|
e_modapi_save(E_Module *m EINA_UNUSED) |
|
{ |
|
e_config_domain_save("module.sysinfo", conf_edd, sysinfo_config); |
|
return 1; |
|
} |
|
|
|
|