Summary:
From UPower 0.99.0, a property "OnLowBattery" was removed and
upower have recommended to use "WarningLevel" instead.
This revision provides "WarningLevel" using the property "DaemonVersion"
and it keeps dealing with "OnLowBattery" as well for old system.
Fixes T1909
Reviewers: gwanglim, barbieri, zmike, stefan_schmidt
Reviewed By: barbieri
Subscribers: zmike, stefan_schmidt, cedric
Differential Revision: https://phab.enlightenment.org/D1717
0.99.0 removed the OnLowBattery property and added the per-device WarningLevel property. this requires what will effectively be a full rewrite of the module to track all the power levels of all the attached batteries and set the ecore power level somehow based on a combination of their levels
since I have no desire to spend any more hours working on and debugging this module which is based on a known-unstable api, I'm making it disable itself if it detects a version >= 0.99.0. hopefully someone will decide to maintain both this and eldbus in the future so that we can more accurately track upstream when they make changes to these things
ref T1908
ref T1909
Being annoyed by different types of eina critical macros - CRI, CRIT,
CRITICAL -, I concluded to unify them to one. Discussed on IRC and
finally, CRI was chosen to meet the consistency with other macros -
ERR, WRN, INF, DBG - in terms of the number of characters.
If there is any missing bits, please let me know.
It's always enabled as it's a dbus module and links to nothing,
actually the daemon doesn't need to be running -- in that case it will
do nothing. In the case the daemon becomes active then it will get the
OnLowBattery property and keep it in sync.
NOTE: I couldn't test the property change as my laptop takes many
hours to get to that situation... let's hope it works :-)
Ecore will now load "system modules" on ecore_init(). The "systemd"
module will use DBus to monitor localed, hostnamed and timedated and
add system events related to those changes.