forked from enlightenment/efl
elm_interface_scrollable: correctly honor looping over
Summary: when looping is enabled, we need to ensure that the correct arrows are enabled. ref D9906 Depends on D9908 Reviewers: zmike Reviewed By: zmike Subscribers: cedric, #reviewers, #committers Tags: #efl Differential Revision: https://phab.enlightenment.org/D9917
This commit is contained in:
parent
ace64dafea
commit
a380a4275a
|
@ -484,6 +484,18 @@ _elm_direction_arrows_eval(Elm_Scrollable_Smart_Interface_Data *sid, Eina_Bool r
|
|||
if (y <= miny) go_up = EINA_FALSE;
|
||||
if (y >= (my + miny)) go_down = EINA_FALSE;
|
||||
|
||||
if (sid->loop_v)
|
||||
{
|
||||
go_up = EINA_TRUE;
|
||||
go_down = EINA_TRUE;
|
||||
}
|
||||
|
||||
if (sid->loop_h)
|
||||
{
|
||||
go_right = EINA_TRUE;
|
||||
go_left = EINA_TRUE;
|
||||
}
|
||||
|
||||
if (!rely_on_cache || go_left != sid->go_left)
|
||||
{
|
||||
if (go_left)
|
||||
|
|
Loading…