elm_image: Remove double callback on mouse_up

In case of MOUSE_UP event, both the hit rectangle and the
smart image object received the event, thus producing double
clicks.
This commit is contained in:
Jean-Philippe Andre 2013-09-27 17:09:36 +09:00
parent 6641cc792e
commit fada635034
1 changed files with 0 additions and 4 deletions

View File

@ -94,8 +94,6 @@ _img_new(Evas_Object *obj)
evas_object_repeat_events_set(img, EINA_TRUE);
evas_object_event_callback_add
(img, EVAS_CALLBACK_IMAGE_PRELOADED, _on_image_preloaded, sd);
evas_object_event_callback_add
(img, EVAS_CALLBACK_MOUSE_UP, _on_mouse_up, obj);
evas_object_smart_member_add(img, obj);
elm_widget_sub_object_add(obj, img);
@ -211,8 +209,6 @@ _elm_image_edje_file_set(Evas_Object *obj,
evas_object_smart_member_add(sd->img, obj);
if (sd->show) evas_object_show(sd->img);
evas_object_clip_set(sd->img, pclip);
evas_object_event_callback_add
(sd->img, EVAS_CALLBACK_MOUSE_UP, _on_mouse_up, obj);
}
sd->edje = EINA_TRUE;