eldbus: Check return value and error out if necessary
Coverity reports that we do not check the return value of _eldbus_model_proxy_load here. We likely should be checking that in case the model proxy fails to load so we can return proper values here. Fixes Coverity CID1355233 @fix Signed-off-by: Chris Michael <cp.michael@samsung.com>
This commit is contained in:
parent
4555f5d594
commit
fb09df7977
|
@ -98,9 +98,13 @@ static Eina_Array const *
|
|||
_eldbus_model_proxy_efl_model_properties_get(Eo *obj EINA_UNUSED,
|
||||
Eldbus_Model_Proxy_Data *pd)
|
||||
{
|
||||
Eina_Bool ret;
|
||||
|
||||
EINA_SAFETY_ON_NULL_RETURN_VAL(pd, NULL);
|
||||
|
||||
_eldbus_model_proxy_load(pd);
|
||||
ret = _eldbus_model_proxy_load(pd);
|
||||
if (!ret) return NULL;
|
||||
|
||||
return pd->properties_array;
|
||||
}
|
||||
|
||||
|
|